Issue Description
The requirement is to Remote Shutdown OTDR, Huawei GPON OLT, for a site as its Temperature is >65 C now and further increasing . Since Quarentene has been applied for the city by government hence no body can access site to manually shut down the equipment. Thus we need whatever possible way to shutdown / lock / disbale / OSS the equipment from NOC.
Product : U2000
Version: U2000 V200R017C60SPC2015
NE PRODUCT : MA5800-X17
VERSION : MA5800V100R019C10
PATCH : SPC208
Solution
confirmed , currently device FTU and OLT doesn’t support remotely shutdown .
But the OLT board can be power off or set to energy-saving mode
For your reference :
board power-off frameid/slotid
board power-on frameid/slotid
huawei(config)#board power-off 0/3 There are services running on the board , this operation will interrupt the services of the board, are you sure to power off the board?(y/n)[n]y The board is being powered off, please wait. The board is powered off successfully
system energy-saving mode [ mode ]
undo system energy-saving mode
huawei(config)#system energy-saving mode { <cr>|mode<E><basic,deep,optimal,standard> }:basic Command: system energy-saving mode basic Set the energy-saving mode successfully
OLT Temperature based on board ,different board settings may different .
Confirmed with R&D ,FTU no such mechanism , it cannot shutdown based on temperature .