The RPS1800 has the following features:
- For non-PoE switches, the RPS1800 can provide 6:1 power redundancy without an 870 W PoE power module:
- The RPS1800 can connect to a maximum of six switches and ensure seamless failover for at most one switch if the internal power module of the switch fails.
- When the internal power module of the switch powered by the RPS1800 recovers, the RPS1800 immediately returns to the backup state.
- Among the six DC output ports, port 1 has the highest priority, and the other ports have the same priority. When the RPS1800 connects to six switches, the switch connected to port 1 preferentially receives power from the RPS1800.
For Huawei S5700-LI and S5700S-LI PoE switches, the RPS1800 supports the forcible PoE power supply mode (default) and the 6:1 power cold redundancy mode.
Forcible PoE power supply mode:- The RPS1800 must be configured with one or two 870 W PoE power modules.
- The forcible PoE power supply mode is the default mode for the PoE switches connected to the RPS1800. In this mode, the RPS1800 provides PoE power supply to the PoE switches. When configured with one 870 W PoE power module, the RPS1800 can provide PoE power supply for only one PoE switch. When configured with two 870 W PoE power modules, the RPS1800 can provide PoE power supply for two PoE switches, 800 W PoE power for each switch.
- The PoE power provided by the RPS1800 and the PoE power of a switch's internal power modules do not accumulate. That is, when a PoE switch is connected to the RPS1800, its maximum PoE power is 800 W.
- When using 110 V power input, each 870 W PoE power module can provide only 400 W of PoE power. In this case, an RPS1800 must be configured with two 870 W PoE power modules if it is used to provide PoE power supply. Additionally, only one port of the RPS1800 can provide PoE power supply for a switch.
- The RPS1800 provides power redundancy for system and PoE power modules of the connected PoE switches. However, it can provide power redundancy for only two PoE switches at the same time.
- The six DC output ports have the same priority.
- You can use the rps cold-backup command to switch to the 6:1 power cold redundancy mode. The S5700-28P-PWR-LI-AC and S5700-52P-PWR-LI-AC do not support the 6:1 power cold redundancy mode.
6:1 power cold redundancy mode:- If the RPS1800 has no 870 W PoE power module, it provides the same functions for PoE switches as it does for non-PoE switches.
- If the RPS1800 has 870 W PoE power modules installed, it provides power redundancy for the system and PoE power modules of PoE switches but does not provide forcible PoE power supply for the switches.
- The RPS1800 can provide PoE power redundancy for only one switch at a time. It requires only one 870 W PoE power module when using 220 V power input and requires two 870 W PoE power module when using 110 V power input.
For S5720-LI PoE switches, the RPS1800 supports the 6:1 power cold redundancy mode.
6:1 power cold redundancy mode:- If the RPS1800 has no 870 W PoE power module, it provides the same functions for PoE switches as it does for non-PoE switches.
- If the RPS1800 has 870 W PoE power modules installed, it provides power redundancy for the system and PoE power modules of PoE switches but does not provide forcible PoE power supply for the switches.
- The RPS1800 can provide PoE power redundancy for only one switch at a time. It requires only one 870 W PoE power module when using 220 V power input and requires two 870 W PoE power module when using 110 V power input.
The 870 W PoE power modules and RPS cables are not hot swappable.
The RPS1800 only provides power redundancy for switches and cannot power on a switch directly.