This section describes the possible causes and handling methods of a board that is offline on the U2000.
Fault Description
40G line board NS3 on Huawei OSN 8800 is offline and unavailable on the U2000 while the other boards are online.
NS3 reports the BD_STATUS alarm.
Procedure
- Cause 1: The slot that houses the board is faulty.
- Reseat Huawei 40G line board NS3 to check whether the fault is removed.
- If the fault persists, change the slot that houses the board.
- Cause 2: The board is faulty.
- Replace the faulty board.