Tuesday, January 30, 2024

Why we cannot query OSNR from NMS by OPM8 board?

This post is about the issue that Impossible to query OSNR from NMS by Huawei OPM8 board. Do have a look below for more information on the topic.

 

Issue Description

Networking Topology:

 

205523o2m5tj6vbojby4xv.png

 

Fault Symptom:

Failed to query OSNR by OPM8 board on site B.

 

205553chhmh0mmm277ox7o.png

Handling Process

1. In 100G system, the OSNR is calculated by EMCA module in the system control board. Even though, query the OSNR by OPM8 board, but it's not calculated by OPM8 direclty.

2. The EMCA module in the system control board performs modeling for each board and fiber type in an OMS trail. During calculation, the EMCA module obtains the input and output multiplexed-wavelength optical power of each OA on the OMS trail, and the single-wavelength signal and noise power scanned by the OPM8 board to calculate the single-wavelength OSNR.

3. So the OSNR calculation depends on the OMS OD route configuration. 

4. Check the "OD Route Configuration" of the OMS between site A and site B, the status is "Partially Created". Try to create once again by clicking "New", it reported "Not Supported Board Type (Error code: 38664)".

 

205627vtt7401xj7ua100p.png

5. Check all the boards on the OMS trail, in Site B, there are 15OAU, 52WSMD9, 55OPM8. Those boards can't be supported by Site A(OptiX OSN8800 UPS V100R012C10SPC300).

6. The Site B is new implemented, some new boards are not supported by Site A. So can't create the "OD Route Configuration". Finally, failed to calculate the OSNR.

Root Cause

The Site B is new implemented, some new boards are not supported by Site A. So can't create the "OD Route Configuration". Finally, failed to calculate the OSNR.

 

Solution

1. Upgrade Site A to R13C10SPC700 or later version, so Site A can support 15OAU, 52WSMD9, 55OPM8.

2. Create the 15OAU, 52WSMD9, 55OPM8 as logic board with the lower version, so Site A can support.

 

Suggestions

1. The OSNR of 100G system is calculated by EMCA module in the system control board, it depend on the OMS and "OD Route Configuration".

2. In the implementation phase, should consider the board can be supported, not only the current device, also should be supported by the peer device of OMS. 

Tuesday, February 23, 2021

How to back Up the NE Database to Huawei OTN SCC Board on U2000?

You need to back up the NE database during daily maintenance, to ensure that OSN6800 OSN8800 SCC board of the NE automatically restores to normal operation after a data loss or equipment power failure. When you back up the NE database to the SCC board, you actually back up the NE data in the DRDB database of the SCC board to the Flash database. When the NE is restarted after a power failure, the SCC board automatically reads the configuration from the FLASH and issues the configuration to the boards.

Prerequisite

You must be an NM user with "NE administrator" authority or higher.

You must log in to the NE as an NE user with system level authority.

Tools, Equipment and Materials

NMS or Web LCT

Precautions

Note: By default, the NMS automatically backs up the NE database into the flash memory every 30 minutes.

Procedure on the NMS

1,Visit the following navigation path.

 


2, Back up the NE database to the TN52SCC or TN11SCC board.

 


Procedure on the Web LCT

1, Select one or more NEs in the NE list. Click BackUp NE Database BackUp to SCC.

Note: The NMS takes a few minutes to back up the NE database. Do not perform any operation in the process of backup.

2, Click OK in the confirmation dialog box.

3, Click Close in the Operation Result dialog box is displayed.