Checking Board Information
When engineers need upgrade Hot Patch of Huawei OptiX NG-SDH, such as Huawei OSN3500, Huawei OSN1500, they must check all boards information.
Description
Check whether all board versions match each
other and determine whether to upgrade the NE according to the board types and
release documents.
Precautions
Ensure that you have obtained the
version mapping table and patch notes.
Procedure
Step 1
Choose Administration > NE
Software Management > NE Data
Backup/Restoration on the main menu.
The Transport/PTN
NE View tab page is displayed.
Step 2
Click to display the Board Information tab page and then
click Query.
Information about all boards will be
displayed.
Step 3
Check the board versions
against the version mapping table. If any version discrepancy occurs, upgrade
or downgrade the board to the mapping version.
Step 4 Query the board
manufacturing information on the NMS or by running the :cfg-get-bddetailinfo:bid command. BD-Name indicates the board type.
Step 5 Check whether a board needs
to be upgraded according to the version mapping table and patch notes.
If an NE supports board-level hot patch
upgrades, the query result helps determine which boards require board-level hot
patches before an upgrade and check whether a board-level hot patch takes
effect after an upgrade.
Follow-up
Procedure
Checking
Whether Any Boards Are Offline or in BIOS State
Perform this task to check whether any
boards are offline or in BIOS state. If any board, especially the standby HUAWEI SCC
board, is offline or in BIOS state, a hot patch upgrade for the NE will fail.
Checking Whether Sufficient Space Is Available on Boards Perform
mapping tablecheck whether sufficient space is available on boards. If the boards do not have sufficient space, the upgrade will fail.