This section describes how to verify Huawei router like NE40E ME60-X8 boards temperature
Procedure
- Run the display temperature[ [ lpu | mpu | sfu ] slot slot-id [ pic pic-id ] ] command to view the temperature status on each board
<HUAWEI> display temperature SlotID2 Base-Board, Unit:C, Slot2 PCB I2C Addr Chl Status Minor Major Fatal Adj_speed Temp TMin Tmax (C) ----------------------------------------------------------------- LPUF 1 1 0 NORMAL 70 80 90 60 70 36 LPUF 1 2 0 NORMAL 60 70 80 50 60 33 LPUF 1 4 0 NORMAL 70 80 90 60 70 35 LPUF 1 5 0 NORMAL 80 90 100 70 80 39 LPUF 1 6 0 NORMAL 70 80 90 60 70 38 LPUF 2 76 1 NORMAL 90 96 102 80 90 39 LPUF 2 76 2 NORMAL 90 96 102 80 90 40 TCMB 1 3 0 NORMAL 70 80 90 60 70 34 TCMB 1 7 0 NORMAL 60 70 80 50 60 31
Pay attention to the values of boldfaced fields displayed. The Temp(C) field indicates the current temperature. The Minor field indicates the threshold of a high temperature for a minor alarm. The Major field indicates the threshold of a high temperature for a major alarm. The Fatal field indicates the threshold of a high temperature for a critical alarm. If the board temperature reaches or exceeds the value of the Fatal field, Huawe ME60 may work abnormally or be damaged.
If the displayed value of the Temp(C) field is lower than that of the Minor field, the board temperature is normal. Then, go on with the subsequent commissioning.
Troubleshooting
If the board temperature exceeds the threshold, perform the following operations:
Check whether fans are faulty and replace any faulty fans.
Check whether the air filter is clogged. If it is clogged, clean it.
Check whether the ambient temperature is too high. If the ambient temperature is too high, lower the temperature in the equipment room.
If the board temperature is still high after the preceding operations, it is due to the high chip temperature. In this case, no action is required or contact Huawei technical support personnel.