How to troubleshoot the fault through the CLI when the service board of Huawei MA5600T/MA5603T/MA5608T is in failed state?

Location Method

When the service board of Huawei MA5600T/MA5603T/MA5608T is in the failed state, locate the fault according to the following procedure:
  1. Check whether the type of the actual used service board is the same as that configured on the system.
  2. Check whether the service board is firmly inserted.
  3. Check whether the power supply of the cabinet is normal.
  4. Replace the original service board with a new service board and then check whether the new service board can start normally.
icon-notice.gif NOTICE:
To facilitate fault report, save the results of the following steps.
When you remove and insert a service board, antistatic measures must be taken.

Procedure

  1. Run the display board frameid/slotid command to query the name of the faulty board, check the type of the actual board inserted in the subrack, and check whether their types are the same.
    • If their types are the same, go to 4.
    • If their types are different, proceed to 2.
  2. If it is confirmed that system configurations are correct, insert a board of the correct type into the slot and then proceed to the next step. If it is confirmed that system configurations are incorrect, run the board delete command to delete the original configurations, after the system displays a message indicating that the board is auto discovered, run the board confirm command to confirm the board and then proceed to the next step.
  3. Wait five minutes and then check whether the fault is rectified.
    • If the fault is rectified, go to 11.
    • If the fault persists, proceed to 4.
  4. Check whether the service board is firmly inserted.
    • If the service board is firmly inserted, go to 6.
    • If the service board is not firmly inserted, remove and insert the service board, and ensure that the service board is firmly inserted. Then, proceed to 5.
  5. Check whether the fault is rectified.
    • If the fault is rectified, go to 11.
    • If the fault persists, proceed to 6.
  6. Check whether the power supply of the cabinet is normal.
    • If the power supply of the cabinet is normal, go to 8.
    • If the power supply of the cabinet is abnormal, check the device supplying power and enable this device to supply power in the normal state. Then, proceed to 7.
  7. Check whether the fault is rectified.
    • If the fault is rectified, go to 11.
    • If the fault persists, proceed to 8.
  8. Replace the original service board, and then check whether the new service board can start normally.
    • If the new service board can start normally, it indicates that service board is faulty. In this case, replace the original service board with a new one. Then, go to 11.
    • If the new service board cannot start normally, proceed to 9.
  9. In the diagnosis mode, run the display reset-record command.
  10. The fault is rectified.

Monday, October 15, 2018

What Are The Differences in the Ring Check Function Between Earlier-Version and Later-Version MA5600T?

  • The processing mechanism of the ring check function of an earlier-version MA5600T has the following disadvantages:
    • After a loop is detected, Huawei MA5600T deactivates the ONT. In this way, live-network configurations are modified.
    • After Huawei ONT like HG8546M is deactivated, you need to manually activate the ONT (that is, re-configure services). This increases the workload.
  • The processing mechanism of the ring check function of MA5600T V800R009 (or later versions) is optimized in terms of the following aspects:
    • After a loop is detected, the MA5600T makes the ONT go offline. In this way, live-network configurations are not modified but the ONT is stopped from transmitting services.
    • The MA5600T automatically makes the offline ONT go online after a period of time elapses. Note that the length of this period of time is configurable.
    • An easy-to-use query function is provided. With this function, you can query all ONTs that go offline because of loops.
  • If you need to query all ONT deactivation records, run the display event history eventid command to query the information about events 0x2910000d and 0x29100026.
Event 0x2910000d indicates the PON port status; event 0x29100026 indicates the non-PON port status.

Friday, July 27, 2018

How to login Huawei HG8310M from MA5600T side by telnet?

Suitable for this scene :  Bridge mode / No U2000 / HG8310M with long distance
Limited condition : The OLT version is later then V8R13C10
Huawei MA5600T>
MA5600T>enable
MA5600T#diagnose
MA5600T(diagnose)#
MA5600T(diagnose)#telnet ont [framid]/[slotid]/[portid] [ontid] ----For OLT V8R13C00 and later version
MA5600T(diagnose)#telnet [framid]/[slotid]/[portid] [ontid]     ----For OLT V8R17C10 and later version
Start to connect to the remote host, press CTRL_] to stop the connection
Trying 192.168.100.1

 ...
Connected to 192.168.100.1

 ...

Thursday, June 14, 2018

What is the System Architecture of Huawei MA5600T/MA5603T/MA5608T?

Huawei MA5600T/MA5603T/MA5608T uses the system architecture containing three modules: M1, M2, and M3.
  • The M1 service port module provides various service access ports, such as PON, P2P, POTS, and Huawei xDSL service ports.
  • The M2 core processing module implements CPU processing, Ethernet switching, and service processing.
  • The M3 uplink port module transmits service flows upstream to network-side devices.
In the preceding figure:
  • The M1 service port module and M3 uplink port module connect to different boards. For details of working principles of each module, see board description in the Hardware Description.
  • For details of service flow directions in the M1 service port module, see board working principles in the Hardware Description.
  • The service flows processed by the M2 core processing module are classified into two types: One type of service flows are transmitted upstream after they are processed by the Ethernet switching module and the M3 uplink port module; the other type of service flows are transmitted upstream after they are processed by the Ethernet switching module, service processing module, and then Ethernet switching module again.

Friday, May 4, 2018

Does Huawei NG-OLT MA5800 Support AC power?

Huawei NG-OLT MA5800 is the industry's first smart aggregation OLT with a distributed architecture. It is positioned as the next-generation OLT for NG-PON. The product is designed to help carriers build networks with larger bandwidths, higher speeds, and smarter connectivity to deliver better service experience.
MA5800 series has 4 model, MA5800 X17, X15, X7 and X2.
MA5800 X17, X15, X7 only has DC power card like Huawei MA5600T and MA5603T; MA5800 X2 can support AC or DC power.
Because high performance, MA5800 is getting more and more popular in global, although MA5800 price is a little more expensive than MA5800T.


Thursday, April 26, 2018

What are the differences in the processing mechanism of the ring check function between earlier-version and later-version MA5600T?

We plan to buy Huawei OLT, What are the differences in the processing mechanism of the ring check function between earlier-version and later-version MA5600T?
  • The processing mechanism of the ring check function of an earlier-version MA5600T has the following disadvantages:
1,After a loop is detected, the MA5600T deactivates the ONT. In this way, live-network configurations are modified.
After the ONT is deactivated, you need to manually activate the ONT (that is, re-configure services). This increases the workload.
  • The processing mechanism of the ring check function of MA5600T V800R009 (or later versions) is optimized in terms of the following aspects:
1, After a loop is detected, the MA5600T makes the ONT go offline. In this way, live-network configurations are not modified but the ONT is stopped from transmitting services.
2, Huawei MA5600T automatically makes the offline ONT go online after a period of time elapses. Note that 3, the length of this period of time is configurable.
3, An easy-to-use query function is provided. With this function, you can query all ONTs that go offline because of loops.
  • If you need to query all ONT deactivation records, run the display event history eventid command to query the information about events 0x2910000d and 0x29100026.

Thursday, April 12, 2018

What's new in MA5600T V800R016C10 compared with previous versions?

Feature Updates

Hardware Updates

H802MABH: Huawei MA5600T A 19-inch backplane supporting VDSL vectoringIt is supported since V800R016C00 and later. If you want to know Huawei VDSL board price, you can contact Thunder Link International sales.

Tuesday, February 27, 2018

How to Display IGMP Messages on Huawei MA5600T

When the multicast duplication point is on Huawei MA5600T, how to display the IGMP messages exchanged between the MA5600T and the upper-layer device and between the MA5600T and IGMP users?

EPBA board:
  • To display the messages, do as follows:
    huawei#terminal debugging
    % Current terminal debugging is on
    huawei#terminal monitor
    % Current terminal monitor is on
    huawei(config)#debugging igmp all
    
  • To cancel the function of displaying the messages, do as follows:
    huawei#undo terminal debugging
    huawei#undo terminal monitor
    huawei#undo debugging igmp
Boards other than the EPBA board:
  • The messages can be displayed only based on the index of the IGMP service port. To display the messages, do as follows:
    huawei#terminal debugging
    % Current terminal debugging is on
    huawei#terminal monitor
    % Current terminal monitor is on
    huawei(config)#debugging igmp service-port 68
    
  • To cancel the function of displaying the messages, do as follows:
    huawei#undo terminal debugging
    huawei#undo terminal monitor
    huawei#undo debugging igmp
  • The preceding methods apply to V800R006C02 and V800R008.
  • After the function of displaying IGMP messages is enabled, the device performance may be affected. Therefore, disable this function when it is not used.

Wednesday, March 22, 2017

How to Search Out the Resource License Fast in a PO?

Q:
Both the resource license for the U2000 software and the NE licenses for hardware devices are contained in a purchase order (PO). The numerous NE licenses in the PO make it difficult to search out the resource license fast.
Alarm Information
None
Handling Process
    A:
In the advanced search window of the FNO system, you can enter multiple search criteria, such as the PO, product name, product version and site information. In this manner, the required license can be located accurately.
Note:
NE licenses are licenses for network hardware devices. Currently, hardware devices can control functions by using NE licenses without executing license policies. Therefore, hardware devices need not use 
license files. The resource license is a license for the U2000 software used to manage specific NE or port resources on the U2000. Usually, the devices at a site share a PO. If capacity expansion is performed at the site, the NE licenses and the resource license that is used to manage those devices will be combined in one PO. As a result, a PO in the FNO system contains numerous NE licenses and one resource license for managing those devices.
Step 1  At the FNO website, click the button highlighted by the red oval as shown in Figure 1-1(check the attachment Figure 1-1 Manage entitlements).
Step 2  In the dialog box that is displayed, enter multiple search criteria as shown in Figure 1-2(check the attachment Figure 1-2 advanced search).
Root Cause
None
Suggestions
None 

More related:

Huawei MA5683T

Huawei MA5680T




Monday, March 20, 2017

Ethernet configuration missing in NMS but normal when testing

Issue Description
Ethernet configuration missing in NMS, already configured at both site. However, when do testing end to end, no faulty alarm at test gear. The services still exist, if not, test gear will show faulty alarm. 
Alarm Information
No Alarm.
Handling Process
1, Current version U2000 V1R3C00SPC100 is upgrading to V1R5C00SPC600 as recommended by R&D.
2, After NMS restart, all Ethernet configurations appear normally.
Root Cause
1, Configuration not seen at NMS, but when test it normal, mean at NE side services were normal.
2, Services only cannot see at NMS side, mean problem probably related to NMS.
3, NE can login and communicate normally, means NMS and NE can communicate normally.

4, Collect data and send to R&D.
5, Feedback from R&D, probably the current NMS version have some bug which cannot support some features of NE or the version of NE and NMS may not compatible. R&D recommended version V1R5C00SPC600 to upgrade.

Suggestions
1, for new version of NE, always uses the latest NMS version to avoid some operations and monitoring failure.
2, V1R5C00SPC600 version is the latest recommended by R&D to use.

More related articles:

MA5600T Series LACP Configuration

MA5600T Series Equipment Downgrade Guidebook

How to configure DHCP on OLT